    he
    8200  AutoSampler
    is a low-loss low-volume autosampler that mounts an all Varian 3000 Series Gas Chromatographs equipped with the In-Board Data Handling (IBDH
    TM
    ) option.
    The 8200  AutoSampler can be installed by you. Once you install the 8200 mounting plates over the GC injector nuts (either front or back mounting), and align the syringe, you can remove and remount the 8200 AutoSampler without the need to realign the syringe again.
    The left-hand mount (storage module swings to the left) of the injector is standard for the Star 3400 CX, 3410, 3500, and the left injectors of the Star 3600 CX GC. An optional right-hand mount (storage module swings to the right) is available for right-hand injectors of the Star 3600 CX GC.
    The 8200 AutoSampler assembly includes: Storage Module, Pneumatics Module, and
    Injection
    Tower
    .
    8200 AutoSampler Features
    •
    Compatible with 1040, 1041, 1060, 1061, 1075 (front position Star 3400 CX only), 1077, and 1093/1094 (SPI) injectors
    •
    Controlled from the GC keyboard or the GC Star Workstation
    •
    Syringe washed with up to two solvents
    •
    Syringe needle depth into vial programmable.
    •
    Syringe plunger setting set easily (Home position alignment)
    •
    Connects to the host GC with one cable
    •
    48 vial capacity carrousel
    •
    Solvent flush sample injection technique
    •
    Injects Neat, Viscous, and Volatile samples
    •
    Accommodates 100, 120, 220, and 240V power
    •
    Pneumatics Module,
    Injection
    Tower
    , and Storage Module combined into a single compact unit
    •
    Pneumatics easily accessible
    •
    Five sampling modes
    8200 AutoSampler Specifications
    Performance
    Peak area:
    <1.0% RSD typical in standard mode for all injector types
    except
    split/splitless
    injectors
    (1075/1077) where typical RSD is <1.5%.
    Carryover:
    <0.05% typical with default values.
    <0.01% when wash cycle is lengthened by increased viscosity factor or with multiple solvent wash.
    Physical
    Height:
    19.5" (49.5 cm)
    Width:
    6.0" (15.5 cm)
    Depth (including
    Storage Module):
    15.75” (40 cm)
    Weight:
    24 Ibs (10.9 kg)
    Sample Capacity:
    48 samples contained in 2 mL screw-cap or 2 mL crimp-top vials, standard micro-vials with internally machined conical volume or National Scientific Target Microvial inserts. These types are mixable within the sample carrousel. Wash vials not required.
    Syringe:
    Flow-through design to allow dynamic washing; standard 10 µL syringe with Teflon®-tipped plunger.
    Sampling Modes:
    Standard, Volatile, Neat, and User Defined
    Programmable
    injection
    Speed:
    0.2 to 10 µL/sec
    Programmable
    residence
    time:
    0 to 10 minutes
    Programmable
    hot
    needle time:
    0 to 1.0 minute
    Sample size:
    Programmable from 0.1 to 5.0 µL with 10 µL syringe.
    Sample waste:
    Less than 0.1 µL per injection in the Solvent Flush Mode.
    Minimum sample
    2 mL vials-300 µL
    volume
    :
    Micro vials-10 µL
    External wash
    solvent
    :
    Choice of solvent A, solvent B, or both.
    Sample coding:
    Racks 1-4; vials 1-12
    Environmental
    For Optimum performance of the 8200 AutoSampler, check that the operating environment meets the following specifications:
    Temperature:
    Operating: 10°C to 40°C
    Storage: -20°C to 65°C
    Humidity:
    Operating: To 80% non-condensing
    Power:
    90 Vac to 264 Vac operating range with four selectable voltages:
    100, 120, 220, 240 Vac (±10%) Frequency: 50/60 Hz
    Power Consumption (Maximum): 55 VA
    The 8200 AutoSampler mounts over the injectors on the top cover of the Varian Series 3000 Gas Chromatographs (with the exception of the 3300). The 8200 AutoSampler is operated through the keypad on the front panel of the GC.
    The AutoSampler is not powered through the GC but through a "power entry module" located on the rear panel of the Pneumatics Module. The main power
    switch,
    fuse(s) and voltage selection components are also located on this rear panel. The AutoSampler can be operated at 100, 120, 220, and 240 Volts, 50/60 Hz, single phase, or split phase (phase/phase) power.
    For the procedure to select the appropriate voltage for the 8200 AutoSampler.
    In order for the 8200 AutoSampler to operate with the 3000 Series GC, the GC must be equipped with the most recent version of the 8200 IBDH/CPU PC Board
    The 8200 CX AutoSampler is constructed of three modules: Storage Module,
    lnjection
    Tower
    Module, and Pneumatics Module.
    Storage Module
    The Storage Module consists of: 48-vial carrousel, turntable, Position Sensor Board, vial sensors, and two synchronous motors that rotate the turntable and move it in and out of the sampling position. The Storage Module is hinged to the
    lnjection
    Tower
    and mounts left-hand (
    standard),
    or right-hand (optional for the Star 3600 CX GC).
    A power ON indicator (LED) is located
    an the
    front right side of the Storage Module. This LED lights when the power cord is properly connected and the power switch of the AutoSampler is turned ON.
    Pneumatics Module
    The Pneumatics Module houses: the solvent and air solenoid valves that control solvent and air to the solvent reservoirs and regulator; power transformer; main power switch, fuses, voltage selection module; and, the Controller PC Board. Gas (at 40-60 psig) enters the pressure regulator preset to 20 psi (outlet) at the factory. You should not need to further adjust the gas pressure. Gas is distributed to Tour valves (L1, L2, L3, L5) that control pressure and solvent flow from Reservoirs A and B. Solenoid valves in the pneumatics module are connected to J8 an the 8200 CX Controller PC Board.
    Injection
    Tower
    Module
    The Injection Tower Module houses the syringe carriage and syringe mounting hardware, syringe carriage drive stepper motor, waste cup, and syringe plunger stepping motor drive assembly. The Injection Module, complete with the hinged Storage Module, bolts to the Pneumatics Module.
    Our Policies Of Trade
    Dear Customer
    Thank you for choosing our product.
    We
    will be
    happy to answer any question you have with a swift reply.
    If you have any problem or issue with your purchase\delivery, do not hesitate to contact us.
    We will do our best to clarify and resolve to your satisfaction.
    Please contact us before leaving a bad feedback or starting a case,
    we can work things out
    - Thank you :)
    When you are happy with your purchase, we would highly appreciate a
    good feedback and a 5 star
    rating.
    Handling & shipping
    All items are being packed carefully and aesthetically with an emphasis for safety of your purchase.
    As environment keepers, all our wrapping materials are reusable and clean.
    We ship worldwide except our exception countries.
    We are professionals; all that depends on our responsibility will be treated with love and perfection.
    We will do our best to help with issues which are "out of our hands" such as shipping delays, damages, losses or other problems.
    Shipping
    We Ship to United States customers and worldwide.
    We use regular air mail,
    registered air mail and fast delivery - EMS and UPS services.
    If you have any special demand, please let us know.
    Packages will be sent only to the address that is provided by eBay, unless the buyer has     ordered us otherwise and we approved that we got his special request.
    The delivery method will depend on the product and its price.
    The customer will be responsible for any import tax or custom charges in his country.
    If you purchase did not arrive in time, Please contact us, We will resolve the issue.
    Payments
    We trade and accept only PayPal payments.
    Return Policy
    No return
    Best regards
    Gold
    Green
    metal.